Combustion Gas Analysis Solutions
Solutions
Mission Statement
To provide the most robust FTIR Technology for gas analysis.
Combustion gas analysis measures the gases produced during combustion. CIC Photonics builds custom analyzers for engine testing, gas turbine optimization, and fire research, serving private and government clients worldwide.
Combustion Gas Analysis System Capabilities
- Continuous sampling analysis
- Turnkey operation
- Low volume sampling cell (43sccm)
- Fast sampling analysis (T90, spectra collection and analysis under 10 secs)
- Up to 40% absolute moisture and 25% CO2 concentration may be present in the sampling cell
- No moisture trap required
- Automated multisampling point available
- Double particle filtration system (25 and 2um standard. Other sizes available)
- Heated sampling probes and lines
- Low ppm Limit of Detection (LOD) for most combustion residual species (NH3, HCl, NO, NO2, N2O, SO2, SO3, CO2, CO, HCHO, etc)
Our combustion analysis meets the guidances for sampling and analysis of toxic gases and vapors in fire effluents using Fourier Transform Infrared spectroscopy (ISO/DIS 19702:2014)
ISO 19702:2024 and FTIR Combustion Gas Analysis
ISO 19702:2024 sets requirements and recommendations for sampling and analyzing toxic gases and vapors in fire effluents using FTIR spectroscopy. It covers sampling systems, instrument parameters, and calibration spectra, providing a framework for measurements in small- and large-scale fire tests.
CIC Photonics builds custom combustion gas analysis systems for fire research applications. System configuration should account for the target gases, expected concentrations, sampling conditions, and measurement requirements of the test method. These details help determine the appropriate analyzer and sampling setup for each research program.
Combustion Engine Analysis, Gas Turbine Testing, and Fire Research Applications
FTIR combustion analyzers are used to measure gas concentrations in engine exhaust, gas turbine emissions, and fire testing environments. By measuring multiple gas compounds simultaneously, these instruments help engineers and researchers assess combustion efficiency, identify harmful emissions, and collect accurate data for testing and regulatory assessments.
Internal Combustion Engine Exhaust Analysis
FTIR combustion gas analysis helps engineers measure exhaust emissions during engine development, performance testing, and emissions compliance assessments. Depending on the instrument’s configuration and calibration, gases measured can include carbon monoxide (CO), carbon dioxide (CO₂), nitrogen oxides (NO and NO₂), nitrous oxide (N₂O), sulfur compounds, unburned hydrocarbons, and formaldehyde (HCHO).
Analyzing heated exhaust samples without removing moisture helps preserve water-soluble gases and provides a more representative measurement of wet exhaust composition.
Gas Turbine Combustion Monitoring
In gas turbine testing, FTIR gas analyzers provide continuous measurements of combustion gases to help engineers assess combustion efficiency and identify signs of incomplete combustion.
Real-time gas measurements allow operators to monitor emission changes under different operating conditions, evaluate combustion performance, and make informed decisions about fuel-to-air ratio adjustments. Fast-response sampling is particularly useful when monitoring changes during turbine operation.
Fire Gas Analysis and Toxicity Testing
FTIR fire gas analysis helps laboratories and researchers identify and measure gases released when materials burn. Common applications include material flammability testing, fire safety research, and the assessment of potentially toxic combustion byproducts.
For testing conducted under ISO 19702:2024, FTIR systems support the sampling and analysis of toxic gases and vapors in fire effluents. Depending on the substances being tested, target gases may include ammonia (NH₃), hydrogen chloride (HCl), sulfur trioxide (SO₃), and nitrous oxide (N₂O). Appropriate limits of detection (LOD), calibration, and sampling conditions are important for reliable measurements.
Configuring a Combustion Gas Analysis System
Combustion gas analysis systems are configured around the test conditions and measurement objectives of each specific application. Key inputs for system specification include:
- Combustion source type (internal combustion engine, gas turbine, fire test rig, or other)
- Target species list and required detection limits
- Expected moisture and CO₂ concentrations in the sample stream
- Number of sampling points and whether automated switching is required
- Heated line lengths and probe requirements
- Response time requirements and data output format
These inputs determine the appropriate gas cell configuration, filtration specification, heated sampling system, and analytical library for the application. For applications with multiple sampling locations, automated multi-point switching can be incorporated into the system design.
The more specific the application details provided, the more accurately we can specify the system for the test environment and measurement requirements
Why Research and Engineering Teams Choose Our Combustion Analyzers
Our combustion gas analysis systems are built around the specific measurement problem rather than a fixed instrument specification. Research labs, engineering teams, and government agencies work with us for several consistent reasons:
- Custom-built for the application: Configuration, gas cell, sampling components, and analytical library are all matched to the specific combustion source and test requirements before manufacture.
- No moisture trap required: Our gas cells handle up to 40% absolute moisture, removing a sample conditioning step and eliminating the associated risk to sample integrity that drying can introduce.
- Government and private sector experience: We supply combustion gas analysis systems to private companies and government clients worldwide, including demanding test, research, and regulatory environments.
- Simultaneous multi-species measurement: A single FTIR analyzer can measure multiple target gases from one sampling system. The gases measured and detection limits depend on the system configuration and application requirements.
- Quality management: CIC Photonics follows ISO 9001:2015 quality management processes.
- Custom engineering: We work with customers to configure combustion gas analysis systems around their application and measurement requirements.
Frequently Asked Questions About Combustion Gas Analysis
What Toxic Species Does FTIR Combustion Gas Analysis Detect?
Target gases can include carbon monoxide (CO), carbon dioxide (CO₂), nitrogen oxides (NO, NO₂ and N₂O), sulfur dioxide (SO₂), sulfur trioxide (SO₃), hydrogen chloride (HCl), ammonia (NH₃), and formaldehyde (HCHO). The gases measured and achievable detection limits depend on the analyzer configuration and sampling conditions.
What Is ISO/DIS 19702 and Which Applications Require Compliance?
ISO/DIS 19702 is the international standard for sampling and analyzing toxic gases and vapors in fire effluents using FTIR spectrometry. It applies to fire testing laboratories, materials flammability programs, and government fire research. The standard sets performance requirements for sampling methodology, measurement accuracy, and species detection.
How Does FTIR Handle the High Moisture Content Typical in Combustion Gas Samples?
Combustion gases from engines, turbines, and fire scenarios carry significant water vapor. FTIR-based combustion analyzers can measure gas samples containing up to 40% absolute moisture without a drying or moisture trap step. This preserves the actual sample composition and avoids altering species concentrations that a drying step could introduce.
How Quickly Does an FTIR Combustion Analyzer Produce Measurement Results?
T90 response time, full spectrum collection, and complete analysis can be completed in under 10 seconds. This supports continuous, near-real-time monitoring during active combustion tests. The speed is particularly valuable in turbine optimization and engine testing, where combustion conditions can change quickly, and engineers need current data to adjust operating parameters.
Can the System Monitor Multiple Sampling Points in the Same Test Rig?
Yes. Automated multi-point sampling configurations allow a single combustion gas analysis system to monitor multiple sampling locations within the same test rig or facility. This is useful for measuring gas composition at different stages of combustion, comparing combustion zones, or monitoring multiple sampling points without deploying separate analyzers at each location.
What Our Clients Say
Request a Custom Combustion Gas Analysis Solution
Combustion gas analysis systems can be configured for engine testing, turbine optimization, fire research, and combustion emissions monitoring applications, with species lists, sampling configurations, and response times matched to the test environment. Speak with a specialist to discuss your application and request a custom quote.
You can also call us at (505) 343-9500 or email request@cicp.com to share details of your combustion monitoring project. View our combustion analyzer and gas cells to learn more about the products used in our combustion gas analysis systems.