Petrochemical Gas Analysis Solutions
Solutions
Mission Statement
To provide the most robust FTIR Technology for gas analysis.
CIC Photonics designs and builds petrochemical gas analysis systems for petrochemical, chemical, natural gas, and industrial process applications that require accurate, continuous gas composition data. Our FTIR-based systems can be configured for demanding petrochemical environments, including corrosive gas streams, high-pressure applications, and hazardous locations.
- Configurations are available for high-pressure petrochemical process applications.
- 24/7 continuous sampling and analysis
- Automated sampling system
- High-pressure analysis configurations available
- C1/D2 or C1/D1 explosion-proof enclosure options available
- SS316L and Hastelloy wetted materials available
- Monitoring of optimal hydrocarbon ratios
- Natural gas analysis for concentrations of different hydrocarbons, antifreeze additives, and impurities.
CIC Photonics can custom-build an analyzer that meets your requirements for high-purity petrochemical gas analysis.
What Is Petrochemical Gas Analysis?
Petrochemical gas analysis is the continuous measurement of gas composition within petrochemical process streams, used to verify hydrocarbon ratios, detect impurities, and confirm that natural gas and other process gases meet the purity and concentration levels a plant requires. Because petrochemical processes can involve high pressures and demanding gas compositions, the analysis system must be configured around the specific process and sampling conditions.
FTIR-based systems measure gas composition by analyzing how infrared-active gas molecules absorb infrared energy, enabling CIC Photonics analyzers to identify multiple hydrocarbon components and impurities from a single sampling system in real time, without disrupting the process.
High-Pressure Hydrocarbon Gas Monitoring for Petrochemical Processes
CIC Photonics petrochemical gas analyzers are built for hydrocarbon gas monitoring in demanding, high-pressure environments, not general-purpose lab conditions.
CIC Photonics systems can be configured for high-pressure petrochemical gas analysis, with Class I, Division 1 or Class I, Division 2 enclosure options and SS316L or Hastelloy wetted materials for corrosive or high-purity gas streams. Automated sampling and continuous analysis support ongoing monitoring of hydrocarbon ratios, gas composition, and impurity levels while reducing dependence on manual sampling.
Configuring a Petrochemical Gas Analysis System
Petrochemical gas analysis systems are configured around the conditions of the specific process and the compounds being measured. Key engineering inputs can include target gases and concentration ranges, process pressure and temperature, sample locations, corrosive compounds, hazardous-area classification, wetted-material requirements, and required data outputs.
These application requirements help determine the appropriate gas cell, sampling configuration, materials, enclosure, and analytical components for the system.
Configuring a Petrochemical Gas Analysis System
CIC Photonics has engineered FTIR-based gas analysis systems since 1994 for semiconductor, chemical, petroleum, environmental, and other industrial applications. Based in Albuquerque, New Mexico, CIC Photonics is ISO 9001:2015 compliant and configures petrochemical gas analysis systems around the process conditions, gas composition, materials, enclosure requirements, and analytical objectives of each application.
- Custom-built systems: Each analyzer is configured for the client’s actual process gas composition, pressure, and enclosure requirements.
- High-pressure engineering: System and gas-cell configurations are available for demanding high-pressure petrochemical applications.
- Material options for corrosive streams: SS316L and Hastelloy wetted materials are available for demanding petrochemical environments.
- ISO 9001:2015-compliant manufacturing: CIC Photonics applies its quality management processes to the design and manufacture of custom analytical instrumentation.
- US-based engineering and support: CIC Photonics is based in Albuquerque, New Mexico, with direct access to the team that designs and builds each system.
Frequently Asked Questions About Petrochemical Gas Analysis
What Is the Role of a Gas Cell in Petrochemical Gas Analysis?
The gas cell provides the optical measurement path through which the gas sample is analyzed by the FTIR system. Gas-cell design influences factors such as optical path length, measurement sensitivity, gas exchange characteristics, pressure capability, and compatibility with the sample being measured.
Why Does Optical Path Length Matter in FTIR Gas Analysis?
Optical path length affects the absorption measurement used to determine gas concentrations. Longer optical paths can support measurements of lower-concentration components, while shorter-path configurations may be appropriate for higher concentrations and other process requirements. The appropriate path length depends on the compounds and concentration ranges being measured.
What Types of Gas Cells Does CIC Photonics Offer?
CIC Photonics manufactures long-path and short-path infrared gas cells for gas analysis applications. Available product families include Ranger and 4Runner long-path cells and Scout, CRV, and Cherokee short-path cells. Gas-cell selection depends on the measurement and application requirements.
How Does FTIR Identify Gases in a Petrochemical Sample?
Gas molecules absorb infrared energy at characteristic wavelengths. An FTIR spectrometer measures this absorption across a spectral range, allowing the analytical system to use the resulting infrared spectrum to identify and quantify configured gas components.
What Is the Difference Between Long-Path and Short-Path Gas Cells?
Long-path gas cells increase the effective optical path traveled by infrared energy through the sample and can support measurements at lower concentrations. Short-path gas cells use a shorter optical path and can be suited to higher-concentration measurements and other application-specific conditions. Cell selection depends on the gases, concentration ranges, pressure, and measurement requirements.
What Our Clients Say
Request a Custom Petrochemical Gas Analysis Solution
Petrochemical gas analysis systems can be configured around your process pressure, gas composition, enclosure, and material requirements described above. Speak with a CIC Photonics product specialist to discuss your application and request a custom quote.
You can also call or email us directly to request a quote or share the details of your petrochemical gas monitoring project.